The broadband induction coil magnetometer MFS-06e has been developed to measure variations of the Earth´s magnetic field, particularly for applications in Magnetotellurics (MT) and Controlled Source Audio Magnetotellurics (CSAMT). It covers a wide frequency range from 0.0001 Hz up to 10 kHz. In spite of its wide bandwidth, the MFS-06e shows outstanding low-noise characteristics, extremely low temperature drift of input offset voltage and offset current and a very stable transfer function over temperature and time. The MFS-06e is the result of many years of experience of metronix in the design, manufacture and application of induction coil magnetometers.
Metronix takes special care of the initial calibration of all MFS-06e magnetometers as part of the ISO9001 certified production process. Tests have demonstrated an excellent long time stability of the transfer function. The integrated calibration facility makes it easy for the user to perform an online calibration or test of the magnetometer´s transfer function. A differential test signal can simply be injected into the CAL input of the sensor
As all sensors of the e-series the MFS-06e has a chip with integrated calibration function and can be auto-detected by the ADU-07e
Frequency range | 0.0001 Hz .. 10 kHz |
Frequency bands | 0.0001 Hz 500 Hz (chopper on) 10 Hz 10 kHz (chopper off) |
Sensor noise | 1.1*10-2 nT/√Hz @ 0.01 Hz 1.1*10-4 nT/√Hz @ 1 Hz 1.0*10-6 nT/√Hz @ 1000 Hz (chopper off) |
Output sensitivity | 0.2 V/(nT*Hz) f << 4 Hz 0.8 V/nT f >> 4 Hz for exact values refer to individual calibration file |
Output voltage range | +/- 10 V |
Function | Induction coil with magnetic field feed back |
Connector | ODU G32KON-T10QJ00-000 (coil socket) ODU S22KON-T10MJG0-7000 (cable plug) |
Calibration input sensitivity | 4 nT / V |
Feedback cut-off frequency | 4 Hz |
Supply voltage | +/- 12 V to +/- 15 V stabilized and filtered |
Supply current | +/- 25 mA |
Case | ruggedized, waterproof case |
Weight | appr. 8.0 kg |
External dimensions | length 1140 mm, diameter 75 mm |
Operating temperature range | -25°C ..... + 70°C |
Description |
---|
Downloads MFS-06e |
This website uses cookies. Those have two functions: On the one hand they are providing basic functionality for this website. On the other hand they allow us to improve our content for you by saving and analyzing anonymized user data. You can redraw your consent to to using these cookies at any time. Find more information regarding cookies on our Data Protection Declaration and regarding us on the Imprint.